YOUR CART [[ chatnum ]]

[[item.Product_num]] * [[item.currency]][[item.price]]

Subtotal: [[currency]][[allPrice]]

CHECKOUT VIEW CART

Price

[[listData.currency]][[listData.discount_price]] [[listData.currency]][[listData.price]] save [[parseInt((1-listData.discount)*100) ]]%
[[listData.product_sku.sku_code.show_name]]
[[item.name]]
more
retract
Please select [[listData.product_sku.sku_code_add.show_name]]
[[listData.product_sku.sku_code_add.show_name]]
ADD TO CART BUY NOW ADD TO CART BUY NOW
christmas vacation deals 2024
Unlock Exclusive Deals Now!
Limited-time special prices shop your favorites before they're gone! Click below to start saving!
Go to see
[[num_page_4]]

Automotive Refrigerant Leak Detector with UV LED and Sensitivity Adjust

$20.25  
[[item.name]] [[pageData.currency]][[item.price]]
Please select [[pageData.product_sku.sku_code_add.show_name]]
ADD TO CART
ADD TO CART

Category: refrigerant detector

Everything About It


SAE-J1627 and EN14624 Certified CLD-100: Stand-Up to False Alarms

Stop False Alarms with Our Solution

Say goodbye to false alarms caused by soap bubbles. The CLD-100 is an advanced detection tool that ensures accurate readings. Developed from the WJL-6000, the CLD-100 is enhanced with UV and white flashlights.

Advanced Detection Capabilities

The CLD-100 is designed for continuous detection of various halogenated gases including CFCs, HCFCs, HFCs, HFOs, hydrocarbons, and blends. With its advanced technology, you can detect CFCs like R12, R11, R500, and R503; HCFCs like R22, R123, and R124; HFCs like R134a, R1234yf, and R404a; HFOs like R1234; hydrocarbons like R290 and R600a; and blends like AZ-50, HP62, MP39, and R410a.

Sensitivity Settings for Optimal Detection

The CLD-100 offers six modes of sensitivity, allowing you to achieve the best detection. With a 20cm flexible sensing tip that maximizes sensitivity at 0.21oz/yr (6gr/yr), you can maneuver the probe as needed. It runs on 4 AAA batteries with a low battery warning to ensure uninterrupted operation.

Quick Warm-Up and Reset Times

With a warm-up time of less than 6 seconds and a reset time of 2 to 10 seconds, the CLD-100 provides fast and accurate readings. The reset function ignores ambient halogen gas levels, ensuring precise detection.

Accurate Zero-Point Calibration

The CLD-100 automatically calibrates its zero point with both visual and audible alerts. After being turned on, it starts beeping and flashing regularly. The closer it gets to a halogen leak, the faster it beeps and flashes, ensuring you are always aware of any leaks.

No False Alarms with Automatic Zero-Point Calibration

Our device automatically focuses on halogen changes to avoid false alarms. The CLD-200 is heated to ensure precise detection, while the CLD-300 features infrared technology that can mute alarms when necessary.

Exceptional Customer Support

Our one-year coverage and continuous customer assistance ensure you have support when you need it. Contact us for effortless support and peace of mind.

ASIN: B09Q13XDZN

ASIN: B09Q5MVSHQ


Automotive Refrigerant Leak Detector with UV LED and Sensitivity Adjust

$20.25  
[[item.name]] [[pageData.currency]][[item.price]]
Please select [[pageData.product_sku.sku_code_add.show_name]]
ADD TO CART
ADD TO CART

Category: refrigerant detector

Everything About It


SAE-J1627 and EN14624 Certified CLD-100: Stand-Up to False Alarms

Stop False Alarms with Our Solution

Say goodbye to false alarms caused by soap bubbles. The CLD-100 is an advanced detection tool that ensures accurate readings. Developed from the WJL-6000, the CLD-100 is enhanced with UV and white flashlights.

Advanced Detection Capabilities

The CLD-100 is designed for continuous detection of various halogenated gases including CFCs, HCFCs, HFCs, HFOs, hydrocarbons, and blends. With its advanced technology, you can detect CFCs like R12, R11, R500, and R503; HCFCs like R22, R123, and R124; HFCs like R134a, R1234yf, and R404a; HFOs like R1234; hydrocarbons like R290 and R600a; and blends like AZ-50, HP62, MP39, and R410a.

Sensitivity Settings for Optimal Detection

The CLD-100 offers six modes of sensitivity, allowing you to achieve the best detection. With a 20cm flexible sensing tip that maximizes sensitivity at 0.21oz/yr (6gr/yr), you can maneuver the probe as needed. It runs on 4 AAA batteries with a low battery warning to ensure uninterrupted operation.

Quick Warm-Up and Reset Times

With a warm-up time of less than 6 seconds and a reset time of 2 to 10 seconds, the CLD-100 provides fast and accurate readings. The reset function ignores ambient halogen gas levels, ensuring precise detection.

Accurate Zero-Point Calibration

The CLD-100 automatically calibrates its zero point with both visual and audible alerts. After being turned on, it starts beeping and flashing regularly. The closer it gets to a halogen leak, the faster it beeps and flashes, ensuring you are always aware of any leaks.

No False Alarms with Automatic Zero-Point Calibration

Our device automatically focuses on halogen changes to avoid false alarms. The CLD-200 is heated to ensure precise detection, while the CLD-300 features infrared technology that can mute alarms when necessary.

Exceptional Customer Support

Our one-year coverage and continuous customer assistance ensure you have support when you need it. Contact us for effortless support and peace of mind.

ASIN: B09Q13XDZN

ASIN: B09Q5MVSHQ


Inficon D-TEK Stratus 724-202 G1 Leak Detector & Monitor
Elitech HVAC Leak Detector - CPU-1G-Sensor
Elitech Professional Halogen Leak Detector
HVAC Refrigerant Leak Detector Kit